Linear Current-Controlled Current Sources (CCCS) |
The general form of the instance is the following:
F<name> <node1(+)> <node2(-)> <Vsource> <value> |
name
Is the name of the component and the initial letter F identifies CCCS.
node1(+), node2(-)
Are the positive and negative nodes, respectively. Current flow is from the positive node, through the source, to the negative node.
Vsource
Is the name of a voltage source through which the controlling current flows. The direction of positive controlling current flow is from the positive node, through the source, to the negative node of Vsource.
value
Is the current gain. Fout = value * I(Vsource).
F1 10 20 VCON 0.001
Linear Voltage-Controlled Voltage Sources
Linear Voltage-Controlled Current Sources
Linear Current-Controlled Voltage Sources
Non-linear Dependent Polynomial Sources
PSpice Non-linear Dependent Sources
Current-Controlled Current Sources Instance
Parameters